LXQII-6KV,LXQII-10KV,LXQII-20KV,LXQII-35KV電壓互(hu)感器中性點消(xiao)諧器
上海經馳 LXQII-10(6) 電壓互感器中性點消諧器 LXQII-10
LXQII型消(xiao)諧(xie)器(qi)(qi)是安(an)裝(zhuang)在(zai)6~35kV中(zhong)(zhong)性(xing)(xing)點不接(jie)地(di)(di)(di)電(dian)(dian)網中(zhong)(zhong)的(de)(de)電(dian)(dian)磁(ci)式電(dian)(dian)壓互(hu)感器(qi)(qi)(以下(xia)簡稱PT),壓變(bian)一(yi)次(ci)側中(zhong)(zhong)性(xing)(xing)點與地(di)(di)(di)之間的(de)(de)高容量非線性(xing)(xing)電(dian)(dian)阻器(qi)(qi),起阻尼(ni)與限(xian)流作(zuo)用,可以有(you)效保護PT以及(ji)PT一(yi)次(ci)側的(de)(de)高壓熔絲(si)。變(bian)電(dian)(dian)站中(zhong)(zhong)性(xing)(xing)點不接(jie)地(di)(di)(di)系(xi)統中(zhong)(zhong),電(dian)(dian)壓互(hu)感器(qi)(qi)常因鐵(tie)(tie)磁(ci)諧(xie)振(zhen)(zhen)而燒毀或熔斷熔絲(si)。人們對(dui)(dui)此做(zuo)了大(da)量的(de)(de)分析(xi)研(yan)究,采取了不少措施(shi)防止(zhi)諧(xie)振(zhen)(zhen)發生(sheng),然而由(you)于(yu)系(xi)統結構的(de)(de)復(fu)雜(za)性(xing)(xing)和運(yun)行(xing)方式的(de)(de)靈活,造(zao)成運(yun)行(xing)參數具有(you)隨機(ji)性(xing)(xing)。同時也因現存的(de)(de)各種消(xiao)諧(xie)措施(shi)的(de)(de)局限(xian)性(xing)(xing),使得只能在(zai)某些情(qing)況下(xia)消(xiao)除諧(xie)振(zhen)(zhen)。電(dian)(dian)壓互(hu)感器(qi)(qi)飽和引(yin)起的(de)(de)鐵(tie)(tie)磁(ci)諧(xie)振(zhen)(zhen)仍然是威脅電(dian)(dian)力系(xi)統安(an)全運(yun)行(xing)的(de)(de)重要原因。因此,有(you)必要在(zai)分析(xi)中(zhong)(zhong)性(xing)(xing)點不接(jie)地(di)(di)(di)系(xi)統鐵(tie)(tie)磁(ci)諧(xie)振(zhen)(zhen)機(ji)理的(de)(de)基礎上探討消(xiao)諧(xie)措施(shi),以便在(zai)實際工作(zuo)中(zhong)(zhong)有(you)針對(dui)(dui)性(xing)(xing)地(di)(di)(di)預防、消(xiao)除中(zhong)(zhong)性(xing)(xing)點不接(jie)地(di)(di)(di)系(xi)統鐵(tie)(tie)磁(ci)諧(xie)振(zhen)(zhen)。
6~35KV中性(xing)點不接地電(dian)(dian)網中的電(dian)(dian)磁(ci)(ci)式電(dian)(dian)壓(ya)(ya)互(hu)(hu)感(gan)器(qi),當母線空載或(huo)出線較少時,因合(he)閘充(chong)電(dian)(dian)或(huo)在運行時接地故(gu)障消(xiao)除等原(yuan)因的激發,會使電(dian)(dian)壓(ya)(ya)互(hu)(hu)感(gan)器(qi)過(guo)飽和,則(ze)可能產生鐵(tie)磁(ci)(ci)諧振過(guo)電(dian)(dian)壓(ya)(ya)。出現相對地電(dian)(dian)壓(ya)(ya)不穩,接地指示(shi)誤動作,PT高壓(ya)(ya)保險絲熔斷等異(yi)常(chang)現象,嚴重(zhong)時會導致(zhi)PT燒毀,繼(ji)而引(yin)發其他事故(gu)。
LXQII型消諧電阻器,是安裝在6~35kV 電磁式電壓互感器一次繞組Y0接(jie)線中(zhong)性(xing)點與地之間(jian)的(de)(de)(de)高容量(liang)非線性(xing)電阻器(qi),起阻尼與限流的(de)(de)(de)作(zuo)用。該消諧電阻器(qi)*符(fu)合(he)現(xian)行電力(li)部標(biao)準DL/T 620—1997《交流電氣裝置的(de)(de)(de)過電壓保護和絕緣配(pei)合(he)》第4.1.5 條中(zhong)的(de)(de)(de)規(gui)定,可(ke)以起到良好的(de)(de)(de)限制電壓互感器(qi)鐵磁諧振的(de)(de)(de)效果。
如果6~35kV電網中性點不接地,母線上Y0接線的PT一次(ci)繞組,將成為該電網對(dui)地*金屬(shu)性通(tong)道。電網對(dui)地電容通(tong)過PT一次(ci)繞組有(you)(you)一個(ge)充放電的過渡過程。試驗測得(de)此時(shi)常常有(you)(you)zui高(gao)(gao)幅值(zhi)達數安(an)培的工頻半波涌(yong)流(liu)通(tong)過PT,此電流(liu)有(you)(you)可能將PT高(gao)(gao)壓熔(rong)絲熔(rong)斷(duan)。而安(an)裝了LXQⅡ系列消諧器(qi)后,這種涌(yong)流(liu)將得(de)到有(you)(you)效抑制,高(gao)(gao)壓熔(rong)絲不再因(yin)為這種涌(yong)流(liu)而熔(rong)斷(duan)。
上海經馳 LXQII-10(6) 電壓互感器中性點消諧器 LXQII-10
消諧器型號:LXQ/RXQ/NLS/GK/QNC高壓消諧器
RXQ-6KV,RXQ-10KV,RXQ-35KV中性點用消諧電阻器
LXQII-6KV,LXQII-10KV,LXQII-35KV壓變中性點用消諧電阻器
LXQII(D)-6KV,LXQII(D)-10KV,LXQII(D)-35KV弱絕緣型高壓消諧器
LXQIII-6KV,LXQIII-10KV,LXQIII-35KV壓變中性點用消諧電阻器
LXQIII(D)-6KV,LXQIII(D)-10KV,LXQIII(D)-35KV弱絕緣型高壓消諧器
LXQ2-6KV,LXQ2-10KV,LXQ2-35KV電壓互感器中性點用高壓消諧器
LXQ2(D)-6KV,LXQ2(D)-10KV,LXQ2(D)-35KV弱絕緣型高壓消諧器
LXQ3-6KV,LXQ3-10KV,LXQ3-35KV電壓互感器中性點用高壓消諧器
LXQ3(D)-6KV,LXQ3(D)-10KV,LXQ3(D)-35KV弱絕緣型高壓消(xiao)諧器
上海經馳 LXQII-10(6) 電壓互感器中性點消諧器 LXQII-10